LTE Scientific manufacture steam sterilizer, autoclave, autoclave manufacturer, autoclave repairs, sterilizer maintenance contracts, laboratory autoclave, autoclave service, testing and calibration, autoclave servicing, sterilizer manufacturer
Home | Site Map | Member Page
LTE manufacture a huge range of autoclaves and sterilizers for laboratories, pharmaceutical and healthcare markets.
LTE also calibrate, validate, test and commission autoclaves to UKAS and HTM2010 standards
LTE Scientific are experts in autoclave safety and repairs. The repair of autoclaves as well as sterilizer maintenance is a core business of LTE.
Email UsTel: +44(0) 1457 876221
Companies around the country and overseas are aware of the service and expertise carried out by our network of autoclave service engineers. Manufacturers of autoclaves and providers of autoclave service and maintenance
Laboratory sterilizers / autoclaves
 
French German Spanish Chinese
 
Home | Products | Autoclaves/Sterilizers | Touchclave-R Autoclaves
Autoclaves/Sterilizers
Touchclave-R Autoclaves

Touchclave-R AutoclavesDesign Features

Autoclaves in the Touchclave-R range are available in seven standard chamber sizes.

Front Loading - 40 70, 150 and 380 litres
Top Loading - 50,100 and 130 litres


All chambers are cylindrical. Steam is generated by heating water in a reservoir within the chamber, with air being removed by upward displacement. Protection against low water level is provided by a cut-out device. A relief valve provides against excess pressure.

The Touchclave-R 40 is designed for bench-mounting. Other models are floor-standing.

Alternative Control System
The Uni-program system stores one program at a time, and is suited to simple repetitive sterilizing applications. Alternatively you can opt for out new Multi-program TouchScreen Control System which offers superb benefits in terms of versatility (click here for more information).

Options and Accessories

Vacuum System/Cat 3
Vacuum System - This high performance system incorporates a liquid ring vacuum pump which provides vacuum conditions of 50mbarA and assists with air removal and cooling/drying. This option can be fitted to all floor standing Touchclave-R models.

When processing cat.3 loads, this option can be fitted in conjunction with the vacuum system. All liquids are returned to the chamber for sterilization, whilst all non-condensable gases pass through a 0.2 micron exhaust filter.

Auto-Fill
To keep the water reservoir in the chamber topped up, an auto-fill system is available on the Touchclave-R 70, 150 and 380. Two types are offered - an automatic system (which is only available if the multi-program control system is fitted) or a push-button system.

Condensate Unit
Available on all models except the 24 and 40 litre. When fitted to the autoclave, it condenses exhaust steam to warm water for draining away, in order to prevent steam entering the workplace or damaging plastic pipework.

NHS Upgrade Package
A number of additional features can be added to bring the autoclave in line with specific requirements of HTM2010.

Containers
In addition to standard shelving, Morrison discard containers, baskets, and loading trolleys are available for handling loads to be processed.

Specifications and Ordering Information
Model Chamber
litres
Loading Chamber dims
mm
Overall Size
HxWxDmm
Weight
kg
Shelves /
positions
TCR/40/H
40
Front
350 x 415
710 x 580 x 720
120
1/1
TCR/60/H 60 Front 350 x 625 1400 x 550 x 970 205 1/1
TCR/60/V 60 Top 350 x 625 1000 x 710 x 540 210 1/1
TCR/120/H 120 Front 500 x 610 1680 x 700 x 1170 260 2/2
TCR/120/V 120 Top 500 x 610 1200 x 890 x 650 265 1/1
TCR/160/H 160 Front 500 x 825 1680 x 700 x 1170 290 2/2
TCR/160/V 160 Top 500 x 825 1200 x 890 x 650 295 1/1
Accessories
TC/TDP/02
Thermal data printer
TC/VAC/R1 Vacuum system for 40 litre unit
TC/VAC/R2 Vacuum system for 60 litre units
TC/VAC/R3 Vacuum system for 120 litre units
TC/VAC/R4 Vacuum system for 160 litre units
TC/IDA/01 Internal data archiving
TC/RDA/01 Remote data archiving with RS232 connection (PC to be supplied by others)
TC/RDA/02 Remote data archiving with RS485 connection (PC to be supplied by others)
TC/FIL/01 Automatic water fill
TC/CON/01 Condensate unit
TC/FIL/01 Cat. 3 effluent retention upgrade (including 0.2micron exhaust filter)
TC/FCB/01 Front panel mounted internal condensate bottle with pull-out compartment
TC/BES/01 Boosted single phase heaters for TCR/40/H
TC/BES/02 Boosted single phase heaters for TCR/60/H
TC/BES/03 Boosted single phase heaters for TCR/60/V
TC/BES/04 Boosted 3-phase heaters for TCR/120/H
TC/BES/05 Boosted 3-phase heaters for TCR/120/V
TC/BES/06 Boosted 3-phase heaters for TCR/160/H
TC/BES/07 Boosted 3-phase heaters for TCR/160/V
TC/KWF/01 Media keep warm facility
TC/MOR/R1 Morrison discard box for TCR/60/H
TC/MOR/R2 Morrison discard box for TCR/120/H
TC/MOR/R3 Morrison discard box for TCR/160/H
TC/MOR/R4 Morrison discard box for TCR/60/V
TC/MOR/R5 Morrison discard box for TCR/120/V
TC/MOR/R6 Morrison discard box for TCR/160/H
TC/BAS/R1 Basket for TCR/60/H
TC/BAS/R2 Basket for TCR/120/H
TC/BAS/R3 Basket for TCR/160/H
TC/BAS/R4 Basket for TCR/60/V
TC/BAS/R5 Basket for TCR/120/V
TC/BAS/R6 Basket for TCR/160V
TC/MEM/01 Increased Cycle Memory
TC/MOD/01 Modem Link
TC/CBD/01 Lockable storage cupboard/support stand for TCR/40/H, including 4 x castors
TC/HST/01 Electric hoist for all top loading models
* = should be specified at the time of ordering.
Use the links below to find out more information

Touch Screen System
Click here to get a quotation on this product...
Top
Autoclaves/Sterilizers | Ovens | Warmed Incubators | Cooled Incubators | Warming Solutions Cabinets | Safety Storage Cabinets | Freeze Dryers | Walk-in Rooms | Drying Cabinets
LTE Scientific Ltd, Greenbridge Lane, Greenfield, Oldham OL3 7EN United Kingdom • Company Registration No. 2648370 (England)
General Enquiry  Telephone: +44(0) 1457 876221  Fax: +44(0) 1457 870131   Email: info@lte-scientific.com
Terms and Conditions | Privacy Statement & Terms of Use