LTE Scientific manufacture steam sterilizer, autoclave, autoclave manufacturer, autoclave repairs, sterilizer maintenance contracts, laboratory autoclave, autoclave service, testing and calibration, autoclave servicing, sterilizer manufacturer
Home | Site Map | Member Page
LTE manufacture a huge range of autoclaves and sterilizers for laboratories, pharmaceutical and healthcare markets.
LTE also calibrate, validate, test and commission autoclaves to UKAS and HTM2010 standards
LTE Scientific are experts in autoclave safety and repairs. The repair of autoclaves as well as sterilizer maintenance is a core business of LTE.
Email UsTel: +44(0) 1457 876221
Companies around the country and overseas are aware of the service and expertise carried out by our network of autoclave service engineers. Manufacturers of autoclaves and providers of autoclave service and maintenance
Laboratory sterilizers / autoclaves
 
French German Spanish Chinese
 
Home | Products | Autoclaves/Sterilizers
Autoclaves/Sterilizers

LTE manufactures autoclaves, or steam sterilizers, for small to large scale applications in the laboratory, healthcare and pharmaceutical sectors.

• Media
• Liquids
• Porous Loads
• Discards, liquid and solid
• Instruments
• Glassware
• Plasticware

LTE has 4 main autoclaves - Touchclave - Lab ('K' & 'F' Models), Touchclave Systems, Falcon Autoclaves and Touchclave-R Autoclaves - covering every type of sterilizing requirement within the laboratory sector of the market. The main features which will determine the most suitable autoclave are shown below.

Just click on the Product Name or Image to get further information.

Touchclave Lab Autoclaves
Touchclave-Lab Sterilizers
Chamber
Shape
Chamber Size
(litres)
Steam
Source
Loading
Method
Control
System
Vacuum Door
Type
Rectangular 150 to 300 External /
In-Chamber
Front Multi Program Optional Sliding
Touchclave-System Autoclaves
Touchclave Systems Autoclaves
Chamber
Shape
Chamber Size
(litres)
Steam
Source
Loading
Method
Control
System
Vacuum Door
Type
Rectangular 326 to 10,000 External Front Multi Program Optional Sliding
Falcon Autoclaves
Falcon Benchtop Autoclaves
Chamber
Shape
Chamber Size
(litres)
Steam
Source
Loading
Method
Control
System
Vacuum Door
Type
Rectangular 30 In-Chamber Front Uni & Multi No Hinged
Touchclave-R Autoclaves
Touchclave-R Autoclaves
Chamber
Shape
Chamber Size
(litres)
Steam
Source
Loading
Method
Control
System
Vacuum Door
Type
Cylindrical 40 to 160 External /
In-Chamber
Front Multi Program Yes Hinged
The following key points may assist you in making your choice

1. Chamber shape and size.
Your choice will depend on the type of load which you wish to process. Rectangular chambers can be more convenient and will hold larger loads, but cylindrical chambers can have a lower purchase price.

2. Steam source.
An external steam source from the autoclave's own generator or from site services has the advantage that the chamber is unencumbered by water and heating elements, with air removal being effected by upward or downward displacement through an appropriate outlet. An in-chamber steam source uses heating elements immersed in water at the bottom of the chamber, with air removal by upward displacement. The initial cost of an in-chamber steam system is less than for external system, but steam generation is slower, maintenance and cleaning costs can be higher, and the load capacity may be less.

3. Front or top loading.
Most models are front loading with horizontal chambers, but some of the Touchclave-R models are top loading with vertical chambers.

4. Multi-program or Uni-program Touchscreen control system.
The multi-program system can store up to 8 different cycle programs, catering for most load types. A load and drain probe are supplied as standard with the system. The alternative uni-program system stores one program at a time, and is suited to simple repetitive sterilizing applications.

5. Vacuum.
Improves the sterilization efficiency by improving air removal at the start of a cycle for certain types of load. It also speeds up the cooling and drying stages of the cycle for all types of load.

Safety and convenience features

The chambers are pressure vessels, built to comply with the European Pressure Equipment Directive 97/23/EC and with other international standards. All pressure vessels are independently certified and have a 10-year integrity warranty.

On all LTE autoclaves, sensors ensure that steam cannot enter the chamber until the door is secure, and that an exhaust valve is released. If an attempt is made to open the door while the chamber is pressurised. An interlock system prevents the door being released until the pressure is at atmospheric level and the temperature has fallen to the programmed safe-offloading level.

Models up to 40 litres in size may be benchtop-mounted. Larger sizes are floor-standing. Castors are fitted to aid movement, and most models will pass through a standard single door.
Top
Autoclaves/Sterilizers | Ovens | Laboratory Incubators | Cooled Incubators | Warming Solutions Cabinets | Safety Storage Cabinets | Freeze Dryers | Walk-in Rooms | Drying Cabinets
LTE Scientific Ltd, Greenbridge Lane, Greenfield, Oldham OL3 7EN United Kingdom . Company Registration No. 2648370 (England)
General Enquiry  Telephone: +44(0) 1457 876221  Fax: +44(0) 1457 870131   Email: info@lte-scientific.com
Terms and Conditions | Privacy Statement & Terms of Use