LTE Scientific products:
LTE Scientific News
Autoclaves with a Green Side
Carbon footprints seem to be on everyones mind at ........
Touchclave-Lab Goes Large
LTE Scientific has introduced six new models to its ........
We are exhibiting at:
Arab Health - Dubai, 23-26 January 2012
Visit us on stand 1A10 to see our range of Endoscope Storage and Sterilization products.
Arab Lab - Dubai, 26-29 March 2012
Visit us on the British pavillion, Stand 743
Caron Photo Stability Chambers

The 6540 Series Photostability Chambers were specifically designed to perform near UV and visual light testing with fluorescent lamps per ICH Q1B Guidelines, Option 2.
This second generation bench-top unit controls light and temperature conditions through an easy-to-use colour touch-screen interface.
Lights automatically shut off after a specified exposure level or time duration. Uniform light distribution and high intensity levels allow quick response for forced degradation testing and confirmatory studies.
Precise humidity control (Models 6545-1, 6545-2 and 6545-3) is achieved through ultrasonic injection and mechanical refrigeration methods.
As with all CARON manufactured products, chambers sold in North America are fully covered by our 12 month standard warranty agreement. Installation and validation services are also available. Please contact your local international distributor for warranty and validation services in other areas.
Standard Features
- Independent control of near UV and cool white VIS lamps are provided to eliminate overexposure for confirmatory tests and provide flexibility for forced degradation studies.
- In “Automatic” mode, lights turn off at the end of a programmed exposure or timed test.
- “Manual” mode allows a flexible test time duration and makes validating the chamber easy.
- Dimmable lamps (230V models) allow testing at specific light intensity levels.
- Programmable alarms notify the user when aging lamps should be replaced.
- Specular aluminium reflective surfaces provide uniform UVA & VIS light reflection and maintain proper SPD (spectral power distribution).
- Stainless steel interior construction provides a smooth, non-porous surface for easy maintenance.
- Two light detectors (one VIS and one UVA) with and integral radiometer are standard and provide precise and accurate light intensity measurements. Light detectors are both cosine corrected and calibrated to NIST traceable standards.
- Precise temperature control is provided through use of a PID controller.
- Humidity controlled units (Models 6545-1, 6545-2 & 6545-3) isolate the effects of hydration during photostability testing.
- Shelves slide out for quick and easy loading and unloading of samples.
- Strategic lamp spacing provides enhanced light uniformity. Overhead lighting results in a large illumination area for maximized direct lighting.
- Door safety switch turns lights off when the door is opened. The lockable door prevents accidental disturbance of in-process tests.
- Two access ports (one per shelf) are standard.
Main Screen Display
- Performance is managed through an eye level, icon-based, colour, touch-screen interface for user convenience.
- The easy-to-use controls are written in multiple languages (English, Spanish, German and French).
- Temperature, humidity and light meters can be quickly programmed. Test results are easy to interpret.
Serviceability
- Pull-out, removable light banks allow for quick bulb replacement without the use of tools.
- Modular refrigeration system and front access, slide-out electrical chassis are easy to service.
- Units contain off-the-shelf components that are readily available.
Specifications and Ordering Information
| Model |
6540-1 | 6545-1 | 6540-2 | 6545-2 | 6540-3 | 6545-3 |
| Catalogue Number |
6540-1 | 6545-1 | 6540-2 | 6545-2 | 6540-3 | 6545-3 |
| Lamp Type, UVA |
Fluorescent, near UV (black lamp | |||||
| Lamp Type, UVA |
Fluorescent, cool white (ISO 10977 compliant) | |||||
| Lamp Type, UVA |
UVA and Visual, calibrated | |||||
| UVA Light Intensity, Typical |
20 W/m sq | 2-30 W/m sq | ||||
| VIS Light Intensity, Typical |
20 klux | 2-35 klux | ||||
| Lamps Dimming |
N/a | 3-100% | ||||
| Typical Time required to reach ICH Recommendation of 200W-hr/m sq |
10 hrs | 7 hrs | ||||
| Typical Time Required to Reach ICH Recommendation of 1.2 million lux-hr |
60 hrs | 35hrs | ||||
| Light Uniformity |
UVA: + 10% VIS + 15% |
UVA: + 10% VIS + 10% |
||||
| Temperature Range |
10°C to 35°C (lights on) | |||||
| Temperature Control |
+ 0.2°C (lights on) | |||||
| Temperature Uniformity |
+ 2.5°C (lights on) | |||||
| Humidity Range |
N/a | 40-70% RH | N/a | 40-70% RH | N/a | 40-70% RH |
| Humidity Control |
N/a | + 3% | N/a | + 3% | N/a | + 3% |
| # of Shelves, Size |
Two (2) Sliding, 26.0”W x 23.1”D x 8.0”H (660 W x 587 D x 203mm H each | |||||
| Usable Shelf Area, Each |
19.0” x 23.0” (483 x 584mm) | |||||
| Usable Shelf Area, Total |
6.1ft sq (0.56m sq) per shelf, 76% of total shelf | |||||
| Maximum Weight per Shelf |
22lbs. (10kg) | |||||
| Interior Surfaces |
Reflective Specular Aluminium | |||||
| Interior Construction |
Stainless Steel | |||||
| Internal Volume |
10.5 ft3, includes lamp space | |||||
| Exterior Dimensions |
37.6” W x 30.2” D x 46.0” H (955 W x 767 D x 1168mm H w/levelling feet | |||||
| Interior Dimensions |
26.9” W x 24.0” D x 28.0” H (683 W x 610 D x 711mm H) | |||||
| # of Access Ports |
Two (2), 1.75” W x 2.0” H (44 W x 51mm H) each | |||||
| Shipping Weight |
700lbs. (900 lbs. With export crate) | |||||
| Electrical Service |
115V, 60 Hz, 15A | 208/230V, 60 Hz, 15A | 230V, 50 Hz, 10A | |||
*RH levels limited by 4C minimum dewpoint
Specifications were established at 20C with 50% RH
Ambient conditions, 115VAC, 60Hz, without lights
Note: Specifications subject to change without notice.
Options & Accessories
| Installation | Installation and start-up. Facility must be equipped with electrical and plumbing requirements |
| VLD640 | Protocol for installation and operation qualification (IQ/OQ), in professional binder |
| VLD641 | Full on-site IQ/OQ/PQ validation. Uses VLD640 protocol (included) |
| REC203 | 3 input, 12” microprocessor based circular chart recorder. For Models 6540-1, 6540-2 & 6540-3. |
| REC204 | 4 input, 12” microprocessor based circular chart recorder. For Models 6545-1, 6545-2 & 6545-3. |
| EXT005 | Extended temperature down to +5°C. (with lights on) |
| EXT045 | Extended temperature up to +45°C. Extended humidity range to 80% for Models 6545-1, 6545-2 & 6545-3. (light bank removed) |
| CRS101 | Condensate Recirculating System |